Merge #1064
1064: Fix LoRaWAN PHY settings for SX126x driver r=Dirbaio a=jbeaurivage While working on #1023 / #1041, I noticed that the `lorawan_device::PhyTxRx` implementation does not conform to the LoRaWAN standard, and therefore devices using this driver could never communicate with a gateway. This PR backports the changes I've made to fix the offending parameters, and I can confirm that the driver now works with LoRaWAN networks. * Set preamble length to 8 symbols * Set polarity to inverted for received messages Co-authored-by: Justin Beaurivage <justin@wearableavionics.com>
This commit is contained in:
commit
bbfb786139
1 changed files with 3 additions and 3 deletions
|
@ -87,7 +87,7 @@ where
|
|||
config.rf.spreading_factor.into(),
|
||||
config.rf.bandwidth.into(),
|
||||
config.rf.coding_rate.into(),
|
||||
4,
|
||||
8,
|
||||
false,
|
||||
true,
|
||||
false,
|
||||
|
@ -119,14 +119,14 @@ where
|
|||
config.spreading_factor.into(),
|
||||
config.bandwidth.into(),
|
||||
config.coding_rate.into(),
|
||||
4,
|
||||
8,
|
||||
4,
|
||||
false,
|
||||
0u8,
|
||||
true,
|
||||
false,
|
||||
0,
|
||||
false,
|
||||
true,
|
||||
true,
|
||||
)
|
||||
.await?;
|
||||
|
|